{"id":18959,"date":"2015-06-05T10:02:15","date_gmt":"2015-06-05T08:02:15","guid":{"rendered":"http:\/\/help.qualiware.it\/qw-help\/?p=18959"},"modified":"2018-04-04T18:32:54","modified_gmt":"2018-04-04T16:32:54","slug":"master-data-management-and-review","status":"publish","type":"post","link":"https:\/\/help.qualiware.it\/qw-help\/master-data-management-and-review\/?lang=en","title":{"rendered":"TOOLS\/EQUIPMENT\/INSTRUMENT REGISTRY"},"content":{"rendered":"<header class=\"entry-header page-header\">\n<p lang=\"en\">The form <strong>&#8220;T<\/strong><b>ools\/equipment\/instrument Registry&#8221;<\/b> allows you to manage the database of all instruments\/equipment the company (both of control and of production);<\/p>\n<p lang=\"en\"><strong>Note<\/strong>: the term &#8216;<strong><span style=\"color: #808000;\">instrument<\/span><\/strong>&#8216; shall mean, unless otherwise noted,both the instrument and the tools used.<\/p>\n<p><a name=\"struttura_scheda\"><\/a>FORM <span lang=\"en\">STRUCTURE<\/span><\/p>\n<p lang=\"en\">The Form, as a whole, looks like in Figure:<\/p>\n<\/header>\n<div class=\"entry-content\">\n<p lang=\"en\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-19893\" src=\"http:\/\/help.qualiware.it\/qw-help\/wp-content\/uploads\/06anastr11_en2.jpg\" alt=\"06anastr11_en\" width=\"685\" height=\"642\" srcset=\"https:\/\/help.qualiware.it\/qw-help\/wp-content\/uploads\/06anastr11_en2.jpg 685w, https:\/\/help.qualiware.it\/qw-help\/wp-content\/uploads\/06anastr11_en2-300x281.jpg 300w\" sizes=\"(max-width: 685px) 100vw, 685px\" \/><\/p>\n<p><span lang=\"en\">The core <\/span><span lang=\"en\">of the form <\/span> <span lang=\"en\">(at the top of the tab) <\/span><span lang=\"en\">contain information that identify the istrument, and is always visible, even changing the lower selecting through the tabs (C<\/span><span lang=\"en\"><i>ontrol and <\/i><\/span><span lang=\"en\"><i>Intervention plan\/Movements\/Information)<\/i><\/span>.<\/p>\n<ol>\n<li lang=\"en\"><a href=\"http:\/\/help.qualiware.it\/qw-help\/anastrumform\/#varstrumform\">control and I<\/a><a href=\"http:\/\/help.qualiware.it\/qw-help\/anastrumform\/#varstrumform\">ntervention plan<\/a> \u2013 opens the scheduling tab uses and required interventions, calling the controls required to ensure the efficiency of the tools and equipment of the company and act promptly when it is needed.<\/li>\n<li lang=\"en\"><a href=\"http:\/\/help.qualiware.it\/qw-help\/anastrumform\/#anastrumform_mov\">Movements <\/a>registers the main data relating to the main uses\/interventions on instruments and equipment, as well as the controls and interventions that are interested<\/li>\n<li lang=\"en\"><a href=\"http:\/\/help.qualiware.it\/qw-help\/anastrumform\/#anastrumform_info\">Information<\/a> \u2013 allows you to connect data and general information to the tools.<\/li>\n<\/ol>\n<p>&nbsp;<\/p>\n<h4><a name=\"nuovo_strumento\"><\/a><span lang=\"en\">TO INSERT A NEW TOOL<\/span><\/h4>\n<p lang=\"en\">The identification key is registered through the two fields:<\/p>\n<ul>\n<li><span lang=\"en\"><span style=\"color: #993300;\"><b>Category<\/b><\/span>: code attributed to the category to which the instrument belongs. <\/span><span lang=\"en\">If you do not remember the coding given to categories, you can invoke the same list with the button <strong>&#8220;Category&#8221; <\/strong><\/span><\/li>\n<li lang=\"en\"><span style=\"color: #993300;\"><b>Code<\/b><\/span>: 10 alphanumeric characters, uniquely identifying the instrument.<\/li>\n<li><span lang=\"en\">Identifying key must be associated with a proper <span style=\"color: #993300;\"><b>Description<\/b><\/span><\/span><\/li>\n<\/ul>\n<p lang=\"en\">Once defined the essential elements is appropriate:<\/p>\n<ol>\n<li lang=\"en\">Indicate the <b>start date using<\/b><\/li>\n<li><span lang=\"en\">Specify if the tool is:<\/span><br \/>\n<span lang=\"en\">\u2013<strong> referece instrument <\/strong>that is used as a reference for the calibration of other instruments;<\/span><br \/>\n<span lang=\"en\">\u2013 <b>mobile tool\/equipment <\/b><\/span>;<br \/>\n<span lang=\"en\">\u2013 <b>subject to the control procedure<\/b>, namely a control intervention or procedure;<\/span><br \/>\n<span lang=\"en\">\u2013 subject to <b>controls<\/b> <b>planning<\/b>, if the control procedure is combined with a planning.<\/span><\/li>\n<li>Finally, selecting &#8220;<a href=\"http:\/\/help.qualiware.it\/qw-help\/anastrumform\/#anastrumform_info\">Information<\/a> Tab&#8221; you can record additional information.<\/li>\n<\/ol>\n<h4><a name=\"nuovo_strumento\"><\/a><span lang=\"en\">SEARCH FOR A TOOL ALREADY ENCODED<\/span><\/h4>\n<p>To search for a tool or equipment already encoded, use the search button <img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-18883\" src=\"http:\/\/help.qualiware.it\/qw-help\/wp-content\/uploads\/01pulsantino_lista1.jpg\" alt=\"01pulsantino_lista\" width=\"41\" height=\"45\" \/>that pops up:<\/p>\n<ul>\n<li><span lang=\"en\">the list of categories of tools \u2013 by double click on the<\/span><span lang=\"en\"> <b>Category <\/b>field<\/span><span lang=\"en\"> or press the button <img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-18882\" src=\"http:\/\/help.qualiware.it\/qw-help\/wp-content\/uploads\/01pulsante_lente1.jpg\" alt=\"01pulsante_lente\" width=\"21\" height=\"21\" \/><b><\/b><\/span>;<\/li>\n<li><span lang=\"en\">the list of instruments in order to Code \u2013 by double click on the <b>Code <\/b>field<\/span>;<\/li>\n<li><span lang=\"en\">the list of instruments in order of Description \u2013 by double click on the field <b>Description<\/b><\/span>.<\/li>\n<\/ul>\n<p lang=\"en\">After you specify a category, by placing in the field code or the field Description, the search button displays only the instruments belonging to the selected category.<\/p>\n<h4 id=\"ipt_kb_toc_15687_4\"><a name=\"interventi_scaduti\"><\/a><span lang=\"en\">INSTRUMENTS AND EQUIPMENT PENDING INTERVENTION<br \/>\n<\/span><\/h4>\n<p lang=\"en\">The <strong>&#8220;pending tasks&#8221;<\/strong> toolbar (in the tab &#8220;<em>Collaboration<\/em>&#8220;) opens the list of planned interventions on tools and equipment already expired or planned for the future:<\/p>\n<p lang=\"en\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-19914\" src=\"http:\/\/help.qualiware.it\/qw-help\/wp-content\/uploads\/06anastr8_en.jpg\" alt=\"06anastr8_en\" width=\"353\" height=\"215\" srcset=\"https:\/\/help.qualiware.it\/qw-help\/wp-content\/uploads\/06anastr8_en.jpg 353w, https:\/\/help.qualiware.it\/qw-help\/wp-content\/uploads\/06anastr8_en-300x183.jpg 300w\" sizes=\"(max-width: 353px) 100vw, 353px\" \/><\/p>\n<p><span lang=\"en\">In particular, the expired date is considered one that is manually inserted in the tab <b>Control and Intervention plan<\/b>, in the <a href=\"http:\/\/help.qualiware.it\/qw-help\/varstrumform#data_prevista_prossimo_intervento\">next action date<\/a><\/span>.<\/p>\n<\/div>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The form &#8220;Tools\/equipment\/instrument Registry&#8221; allows you to manage the database of all instruments\/equipment the company (both of control and of production); Note: the term &#8216;instrument&#8216; shall mean, unless otherwise noted,both the instrument and the tools used. FORM STRUCTURE The Form, as a whole, looks like in Figure: The core of the form (at the top&hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"ngg_post_thumbnail":0,"footnotes":""},"categories":[14],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/help.qualiware.it\/qw-help\/wp-json\/wp\/v2\/posts\/18959"}],"collection":[{"href":"https:\/\/help.qualiware.it\/qw-help\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/help.qualiware.it\/qw-help\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/help.qualiware.it\/qw-help\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/help.qualiware.it\/qw-help\/wp-json\/wp\/v2\/comments?post=18959"}],"version-history":[{"count":0,"href":"https:\/\/help.qualiware.it\/qw-help\/wp-json\/wp\/v2\/posts\/18959\/revisions"}],"wp:attachment":[{"href":"https:\/\/help.qualiware.it\/qw-help\/wp-json\/wp\/v2\/media?parent=18959"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/help.qualiware.it\/qw-help\/wp-json\/wp\/v2\/categories?post=18959"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/help.qualiware.it\/qw-help\/wp-json\/wp\/v2\/tags?post=18959"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}